Brands |
N/A Nationwide Boiler's |
Design Pressure |
N/A 650 psig |
Operating Pressure |
N/A 150 to 600 psig |
Boiler Capacity |
N/A 50,000 lb/hr |
Natural Gas Consumption Rate1 | N/A 61,000 SCFH |
Number 2 Fuel Oil Consumption Rate |
N/A 460 gal/h |
Main Steam Connection Size |
N/A 6 in |
Main Steam Connection Type |
N/A 600# FLG |
Natural Gas Connection Size |
N/A 4 in |
Natural Gas Connection Type |
N/A 150# FLG |
Feedwater Connection Size |
N/A 2 in |
Feedwater Connection Type |
N/A 600# FLG |
Bottom Blowdown Connection Size |
N/A 1-1/2 in |
Bottom Blowdown Connection Type |
N/A 600# FLG |
Continuous Blowdown Connection Size |
N/A 1 in |
Continuous Blowdown Connection Type |
N/A NPT |
Instrument Air Connection Size |
N/A 1/4 in |
Instrument Air Connection Type |
N/A NPT |
Electrical Power Service Requirements |
N/A 480 VAC, 3 ph, 60 hz, 90 AMPS |
Length |
N/A 51 ft 10 in. |
Width |
N/A 11 ft 7 in. |
Height |
N/A 14 ft 0 in. |
Shipping Weight |
N/A 79,000 lb |
Operating Weight |
N/A 91,050 lb |
Nitrogen Oxide (NOx) Emission Rate (Correlated to 3 Percent (%) Oxygen (O2)) |
N/A 30 ppm |
Carbon Monoxide (CO) Emission Rate (Correlated to 3 Percent (%) Oxygen (O2)) |
N/A 50 ppm |
Additional Information |
N/A