COMPANY HEADER
Print Back
Nationwide Boiler's 40,000 pph, 700 psig saturated steam, trailer-mounted package watertube boiler is set to burn natural gas (#2 oil is optional). It is fully piped and wired and includes a low NOx burner, EconoStak economizer, PLC-based control system, non-return valve and steam stub stack. Optional CataStakā„¢ SCR System can be supplied for ultra low NOx compliance.
Unit of Measure

Specifications

Brands

N/A Nationwide Boiler's
Natural Gas Consumption Rate1 N/A 54,600 SCFH

Number 2 Fuel Oil Consumption Rate

N/A 382 gal/h

Design Pressure

N/A 700 psig

Operating Pressure

N/A 150 to 650 psig

Boiler Capacity

N/A 40,000 lb/hr

NBI Tag #

N/A B420

Connection Sizes

Main Steam Connection Size

N/A 6 in

Main Steam Connection Type

N/A 600# FLG

Natural Gas Connection Size

N/A 3 in

Natural Gas Connection Type

N/A 150# FLG

Number 2 Fuel Oil Supply Connection Size

N/A 2 in

Number 2 Fuel Oil Supply Connection Type

N/A 150# FLG

Number 2 Fuel Oil Return Connection Size

N/A 1 in

Number 2 Fuel Oil Return Connection Type

N/A 150# FLG

Feedwater Connection Size

N/A 2 in

Feedwater Connection Type

N/A 600# FLG

Bottom Blowdown Connection Size

N/A 1-1/2 in

Bottom Blowdown Connection Type

N/A 600# FLG

Continuous Blowdown Connection Size

N/A 1 in

Continuous Blowdown Connection Type

N/A NPT

Chemical Feed Connection Size

N/A 1/2 in

Chemical Feed Connection Type

N/A NPT

Atomizing Air Connection Size

N/A 3/4 in

Atomizing Air Connection Type

N/A NPT

Atomizing Steam Connection Size

N/A 3/4 in

Atomizing Steam Connection Type

N/A NPT

Instrument Air Connection Size

N/A 3/4 in

Instrument Air Connection Type

N/A NPT

Water Column Drain Connection Size

N/A 3/4 in

Water Column Drain Connection Type

N/A NPT

Electrical Power Service Requirements

Electrical Power Service Requirements

N/A 460 VAC, 3 ph, 60 hz, 100 AMPS

Dimensions and Weights

Length

N/A 51.10 ft

Width

N/A 10.0 ft

Height

N/A 14.0 ft

Shipping Weight

N/A 80,290 lb

Operating Weight

N/A 95,640 lb

Emissions Data (Natural Gas)

Nitrogen Oxide (NOx) Emission Rate (Correlated to 3 Percent (%) Oxygen (O2))

N/A 30 ppm

Carbon Monoxide (CO) Emission Rate (Correlated to 3 Percent (%) Oxygen (O2))

N/A 50 ppm
  • 1 At 15 psi regulated pressure