COMPANY HEADER
Request Information
Nationwide Boiler's 82,500 pph, 350 psig saturated steam, trailer-mounted package watertube boiler is set to burn natural gas (#2 oil is optional). It is fully piped and wired and includes a low NOx burner, EconoStak economizer, PLC-based control system, non-return valve and steam stub stack. Optional CataStak™ SCR System can be supplied for ultra low NOx compliance.
Unit of Measure

Specifications

Brands

N/A Nationwide Boiler's

Design Pressure

N/A 350 psig

Operating Pressure

N/A 100 to 320 psig

Boiler Capacity

N/A 82,500 lb/hr

NBI Tag #

N/A Various

Fuel Consumption

Natural Gas Consumption Rate1 N/A 99,900 SCFH
Number 2 Fuel Oil Consumption Rate2 N/A 700 gal/h

Connection Sizes

Main Steam Connection Size

N/A 8 in

Main Steam Connection Type

N/A 300# FLG

Natural Gas Connection Size

N/A 4 in

Natural Gas Connection Type

N/A 150# FLG

Number 2 Fuel Oil Supply Connection Size

N/A 1-1/4 in

Number 2 Fuel Oil Supply Connection Type

N/A 150# FLG

Number 2 Fuel Oil Return Connection Size

N/A 3/4 in

Number 2 Fuel Oil Return Connection Type

N/A 150# FLG

Feedwater Connection Size

N/A 3 in

Feedwater Connection Type

N/A 300# FLG

Bottom Blowdown Connection Size

N/A 1-1/2 in

Bottom Blowdown Connection Type

N/A 300# FLG

Continuous Blowdown Connection Size

N/A 1 in

Continuous Blowdown Connection Type

N/A NPT

Chemical Feed Connection Size

N/A 1 in

Chemical Feed Connection Type

N/A NPT

Atomizing Air Connection Size

N/A 1 in

Atomizing Air Connection Type

N/A 150# FLG

Atomizing Steam Connection Size

N/A 1 in

Atomizing Steam Connection Type

N/A 150# FLG

Instrument Air Connection Size

N/A 1/2 in

Instrument Air Connection Type

N/A NPT

Water Column Drain Connection Size

N/A 3/4 in

Water Column Drain Connection Type

N/A NPT

Electrical Power Service Requirements

Electrical Power Service Requirements

N/A 480 VAC, 3 ph, 60 hz, 250 AMPS

Dimensions and Weights

Length3 N/A 45 ft 2 in.

Width

N/A 10 ft 7 in.

Height

N/A 13 ft 5 in.

Shipping Weight

N/A 92,000 lb
Operating Weight4 N/A 121,500 lb

Emissions Data (Natural Gas)

Nitrogen Oxide (NOx) Emission Rate (Correlated to 3 Percent (%) Oxygen (O2))

N/A 30 ppm

Carbon Monoxide (CO) Emission Rate (Correlated to 3 Percent (%) Oxygen (O2))

N/A 50 ppm
  • 1 At 20 psi regulated pressure
  • 2 Optional
  • 3 Less removable rear axle and gooseneck / weight includes economizer
  • 4 Less removable rear axle and gooseneck / weight includes economizer